FiberLabs Inc

L-band EDFA

L-band EDFA
  • L-band EDFA

L-band EDFA

The AMP-FL5001-LB Series is a 19-inch rack mount EDFA in the L-band. Combined with the AMP-FL501x-CB series C-band EDFA, it enables the expansion of transmission bandwidth beyond the C-band. This L-band amplifier offers a high output power and flat signal gain over a wide range covering 1560-1610nm, enabling highly reliable WDM/DWDM transmission in the L-band.

Product Type : Rack Mount

Operating Wavelength:1560 nm ~1610 nm

Contact Sales

FEATURES

  • Proven in Valious Deployment Conditions (from R&D to Actual Network)
  • Monitoring/Logging/Interlocking Function
  • RS-232C
  • SNMP Option

APPLICATIONS

  • Telecom Network
  • Datacom Network
  • Increasing Link Budget
  • Loss Compensation

MAIN SPECS

Product Number Operating
WaveLength
(nm)
Nominal
WL
(nm)
Output
Power
(dBm)
(*1)
Gain
(dB)
(*2)
NF
(dB)
(*2)
IN/OUT
Fiber
Standard
Connector
IN/OUT
Isolator
Std. Dimension
(H x W x D, mm)
(*3)
AMP-FL5001-LB-13 1560 to 1610 1580 ≥ +13 ≥ 25 ≤ 6 SMF (*4) SC/PC Built In 43 x 440 x 403
AMP-FL5001-LB-16 1560 to 1610 1580 ≥ +16 ≥ 30 ≤ 6 SMF (*4) SC/PC Built In 43 x 440 x 403
AMP-FL5001-LB-19 1560 to 1610 1580 ≥ +19 ≥ 35 ≤ 6 SMF (*4) SC/PC Built In 43 x 440 x 403
AMP-FL5001-LB-22 1560 to 1610 1580 ≥ +22 ≥ 35 ≤ 6 SMF (*4) SC/PC Built In 43 x 440 x 403


(*1) Input Power: 0 dBm @ Nominal Wavelength
(*2) Input Power: -30 dBm @ Nominal Wavelength
(*3) Does not include protrusions
(*4) G.652 compliant (e.g. SMF28)

OTHER SPECS

Attribute Specification
Control Mode ACC (Auto Current Control) and ALC (Auto Light Control)
Monitor & Alarm Input power / Output power / Pump LD current / Pump LD temperature / Case temperature / Power-Supply-Unit voltage (alarm only) / Fan Rotation (alarm only)
Safety Function Interlock with input level Alarm
Remote Interface RS-232C / Relay terminal for alarm
Temperature Operation : 0 to 40 ºC / Storage : -10 to 60 ºC
Power Supply AC 100 to 240 V (50/60 Hz), Redundant and Hot-Swap
Humidity 5 to 80 % RH (non-condensing)
Other Environmental Conditions Indoor use / Overvoltage category: II / Altitude:
Safety Standards IEC 60825-1 (JIS C 6802) / CE marking (EN 61010-1 / EN 61326-1)

Options

Number Option
-011 FC/PC Connector
-012 FC/APC Connector
-014 SC/APC Connector
-019 Other Cusomized Connector
-023 DC 48V Hot Swap Power Supply
-029 Other Cusomized Power Supply
-092 Ethernet Interface
-093 Reflection Monitor and Interlock
-151 Front Control Panel and Display

Gain/noise figure vs. wavelength (FL5001-LB-13)
Gain/noise figure vs. wavelength (FL5001-LB-13)
Gain/NF/output power vs. input power @1580 nm (FL5001-LB-13)
Gain/NF/output power vs. input power @1580 nm (FL5001-LB-13)
Gain/noise figure vs. wavelength (FL5001-LB-16)
Gain/noise figure vs. wavelength (FL5001-LB-16)
Gain/NF/output power vs. input power @1580 nm (FL5001-LB-16)
Gain/NF/output power vs. input power @1580 nm (FL5001-LB-16)
Gain/noise figure vs. wavelength (FL5001-LB-19)
Gain/noise figure vs. wavelength (FL5001-LB-19)
Gain/NF/output power vs. input power @1580 nm (FL5001-LB-19)
Gain/NF/output power vs. input power @1580 nm (FL5001-LB-19)
Gain/noise figure vs. wavelength (FL5001-LB-22)
Gain/noise figure vs. wavelength (FL5001-LB-22)
Gain/NF/output power vs. input power @1580 nm (FL5001-LB-22)
Gain/NF/output power vs. input power @1580 nm (FL5001-LB-22)

REGISTERED USERS ONLY

  • AMP-FL-RM1U-001_drawing_AC.pdf